HL-T1 series

Data sheet HL-T1 Data sheet HL-T1 (0.59MB)
Manuals, software, other downloads Manuals, software, other downloads
Print this page Print this page
HL-T1 sensor
The HL-T1 is an ultrasmall laser thru-beam sensors with very high resolution. Three different types are available: HL-T1001A with a 1mm laser beam which is able to detect object 8µm in diametre at a distance of 500mm between receiver and transmitter; HL-T1005A and HL-T1010A with a laser collimator which produces a light curtain of 5mm or 10mm width respectively. The red semiconductor LED, which belongs to laser class 1, makes it possible to use HL-T1 without any safety requirements.

Characteristics:

  • Resolution max. 4µm
  • Red light semiconductor LED belongs to laser class 1
  • Sensing range up to 2m (HL-T1001A)
  • Min. sensing object 8µm diametre (HL-T1001A)
  • Compact design

 

Options:

  • Side view (HLT1SV1/HLT1SV2)
  • Extension cable (4 / 8m)

  HLT1001A HLT1005A HLT1010A
Laser Class 1
Sensing diameter/width Ø 1mm Ø 1 to
2.5mm
5mm 10mm
Sensing range 500mm 500 to 2000mm 500mm
Resolution 4µm -- 4µm
Min. sensing object (Ø) >/= 8µm >/= 50µm >/= 50µm >/= 100µm
Laser wavelength 650nm
Max. laser output 0.2mW 0.35mW
Housing material Plastic
Protection IP40
Size (HxWxL) Transmitter: 15x15x34mm
Receiver: 15x15x19mm
Transmitter: 20x20x42 mm
Receiver.: 20x 20x25mm
Connection method Cable 0.5m
Usable ambient temp. 0°C to +50°C
Weight 30g 30g 50g
HL-T1 controller
The intelligent, compact controller HL-AC1 can be used with any HL-T1 sensor head, enabling extreme flexibility.It is also easy to exchange just the controller or head in maintenance and service matters. You merely need connect the computation unit (optional) between two controllers to enable addition and subtraction to be carried out for two sensors. A digital controller is not necessary.

Characteristics:

  • Analogue voltage or analogue current adjustable
  • Scaling
  • Zero point and offset adjustment
  • Judgement output (teach-in)
  • Timer (ON/OFF delay)
  • Mutual interference prevention (HL-AC1-CL)
  • Computation unit HL-AC1-CL (optional)

NPN output HLAC1
PNP output HLAC1P
Display LED, 5 digits
Measuring cycle 150µs
Analogue output ±4V, 4 -20mA
Transistor outputs Max. 100mA, 30V DC
Current consumption 190mA or less
Housing material Plastic
Size (HxWxL) ) 30 x 34.3 x 64.3mm
Connection method to power supply Cable 2m
Operating voltage 12 - 24V DC (±10%)
Usable ambient temp. 0°C to +50°C
Temperature characteristics 0.2% F.S. /°C
Weight (approx.) 140g
HL-T1 typical applications

Sheet width measurement to determine glass opacity

Checking the position of chips

Detecting defective lead frame seating



 


More information

 