| Type |
Master unit |
Slave unit |
| High-performance |
High-performance |
Wire-saving |
| Model No. |
NPN output |
HG-TC101 |
HG-TC111 |
HG-TC113 |
| PNP output |
HG-TC101-P |
HG-TC111-P |
| Compatible sensor head |
HG-T1010, HG-T1110 |
| Number of connectable units |
Up to 15 slave units can be connected per master unit. |
| Supply voltage |
24V DC ±10%, including ripple 0.5V (P-P) |
| Current consumption (note 2) |
Max. 100mA (when sensor head is connected) |
| Analog output |
Current output (note 3) |
Current output range: 4 to 20mA / F.S. (default value) |
|
| Error output: 0mA |
| Linearity: ±0.25% F.S. |
| Load impedance: max. 250Ω |
| Voltage output |
Voltage output range: 0 to 5V / F.S. (default value) |
|
| Error output: 5.2V |
|
| Linearity: ±0.05% F.S. |
|
| Load impedance: max. 250Ω |
|
Control output
(output 1, output 2, output 3) |
NPN output type
- NPN open collector transistor
- Max. current: 50mA (note 4)
- Applied voltage: max. 30V DC (between output and 0V)
- Residual voltage: max. 1.5V (at 50mA)
- Leakage current: max. 0.1mA
PNP output type:
- PNP open-collector transistor
- Max. current: 50mA (note 4)
- Applied voltage: max. 30V DC (between output and +V)
- Residual voltage: max. 1.5V (at 50mA)
- Leakage current: max. 0.1mA
|
– |
| Short-circuit protection |
Incorporated (automatic reset type) |
– |
| Judgment output |
NO / NC switching method |
– |
| Alarm output |
Open when alarm occurs |
– |
External input
(input 1, input 2, input 3) |
NPN output type
- Non-contact input or NPN open-collector transistor
- Input conditions: invalid (+8V to +V DC or open), valid (0 to +1.2V DC)
- Input impedance: approx. 10kΩ
PNP output type:
- Non-contact input or PNP open-collector transistor
- Input conditions: Invalid (0 to +0.6V DC or open), valid (+4V to +V DC)
- Input impedance: approx. 10kΩ
|
– |
| |
Trigger input |
Input time min. 2ms (ON) |
| |
Laser emission stop input |
Input time min. 20ms (ON) |
| |
Preset input |
Input time min. 2ms (ON) |
| |
Reset input |
Input time min. 20ms (ON) |
| |
Bank input A / B |
Input time min. 20ms (ON) |
| Sampling cycle |
1ms (standard sampling) / 0.5ms (high-speed sampling) |
| Averaging (selectable) |
1 time (2ms), 2 times (3ms), 4 times (5ms), 8 times (9ms), 16 times (17ms), 32 times (33ms), 64 times (65ms), 128 times (129ms), 256 times (257ms), 512 times (513ms), and 1024 times (1025ms) |
| Display resolution |
0.1μm |
| Display range |
-199.9999 to 199.9999mm |
| Degree of pollution |
2 |
| Altitude |
Max. 2000m |
Environmental
resistance |
Degree of protection |
IP40 (IEC) |
| Ambient temperature |
Operation: -10 to +50°C (no condensation or ice)
Storage: -20 to +60°C |
| Ambient humidity |
35 to 85% RH, at storage: 35 to 85% RH |
| Insulation resistance |
Min. 20MΩ with 250V DC megger between all supply terminals connected together and enclosure |
| Voltage withstandability |
1000V AC for one minute between all supply terminals connected together and enclosure |
| Vibration resistance |
10 to 150Hz frequency, 0.75mm amplitude in X, Y and Z directions for two hours each |
| Shock resistance |
98m/s² acceleration (10G approx.) in X, Y and Z directions five times each |
| Material |
Case: polycarbonate, cover: polycarbonate, keys: polyacetal |
| Cable |
0.2mm² 2-core cable (brown and blue lead wires) / 0.15mm² 7-core composite cable, 2m long |
0.15mm2 7-core composite cable, 2m long |
– |
| Weight (approx.) |
140g |
140g |
60g |